Alloynex supplies steel tubes and pipes from Jaipur, Rajasthan, for engineers and buyers who need more than a length of steel. Each order is checked against your standard, your size and wall, and your service – pressure, temperature or precision. Ask for heat numbers on each length; we check this in the technical review.
Send your drawing or line list for a technical review – info@alloynex.com
Pipe or tube? Two different ways of buying the same steel
Buyers often use “pipe” and “tube” as the same word. Standards do not. The difference decides how you write your order.
| Pipe | Tube | |
|---|---|---|
| Main job | Carry a fluid or gas | Do a mechanical, structural or heat-transfer job |
| How size is given | Nominal pipe size (NPS or NB) + schedule or class | Exact outside diameter (OD) + exact wall thickness |
| What matters most | Bore (flow) and pressure rating | OD, wall and tolerance |
| Typical standards | ASME B36.10M sizes; ASTM A53, A106, API 5L; IS 1239, IS 3589 | ASTM A179, A192, A210, A513, A519; EN 10305; IS 1161, IS 4923 |
| Example on an order | NPS 4, Sch 40, ASTM A106 Gr B, seamless | 25.4 mm OD x 2.11 mm wall, ASTM A179, cold drawn |
Rule of thumb: if your drawing gives NPS and schedule, you are buying pipe. If it gives OD and wall in millimetres with a tolerance, you are buying tube.
How they are made: seamless and welded
- Seamless – a solid round billet is pierced and rolled into a hollow, then hot finished or cold drawn. No weld seam. Chosen for high pressure, high temperature and critical service.
- ERW (electric resistance welded) – steel strip is formed into a round and the edges are welded along the length. Tight wall tolerance and a clean surface. Widely used for water, structural, mechanical and many process lines.
- Cold drawn – seamless or welded tube drawn again through a die, cold. Closer OD and wall tolerance and a smoother surface, for precision and heat-exchanger work.
Read more: ERW vs seamless pipes – key differences for plant buyers
Common standards by service
This table is a buyer guide, not a supply list. Tell us your standard and grade, and we confirm it in the technical review.
| Service | Common standard and grade | Made as |
|---|---|---|
| General water, air and gas lines (India) | IS 1239 Part 1 – Light, Medium, Heavy (6 to 150 NB) | ERW or seamless |
| Large water and sewage lines (India) | IS 3589 – Fe 330, Fe 410, Fe 450 | Welded |
| General process and utility lines | ASTM A53 Gr A, Gr B | ERW or seamless |
| High temperature process and steam | ASTM A106 Gr B, Gr C | Seamless |
| Oil and gas line pipe | API 5L Gr B, X42 to X70 (PSL1 / PSL2) | ERW, seamless or SAW |
| Low temperature service | ASTM A333 Gr 6 | Seamless or welded |
| High temperature alloy (power, refinery) | ASTM A335 P11, P22, P91 | Seamless |
| Heat exchanger and condenser tubes | ASTM A179 | Seamless, cold drawn |
| Boiler tubes | ASTM A192, ASTM A210 Gr A1 / Gr C | Seamless |
| Mechanical and precision tubes | ASTM A513 (ERW), ASTM A519 (seamless), EN 10305-1 / -2 | ERW, seamless, cold drawn |
| Structural hollow sections | IS 1161, IS 4923 | ERW or seamless |
Our range
Tell us the standard, grade and size on your drawing, and our team confirms supply in the technical review.
Sizes and schedules in one view
For pipe, the nominal size is not the real outside diameter up to NPS 12. From NPS 14 upward, NPS and OD are the same number in inches. The schedule sets the wall.
| NPS (inch) | NB (mm) | OD (mm) | Sch 40 wall (mm) | Sch 80 wall (mm) |
|---|---|---|---|---|
| 1/2 | 15 | 21.3 | 2.77 | 3.73 |
| 1 | 25 | 33.4 | 3.38 | 4.55 |
| 2 | 50 | 60.3 | 3.91 | 5.54 |
| 4 | 100 | 114.3 | 6.02 | 8.56 |
| 6 | 150 | 168.3 | 7.11 | 10.97 |
| 8 | 200 | 219.1 | 8.18 | 12.70 |
Source: ASME B36.10M. IS 1239 pipes follow the same ODs for most sizes but use Light, Medium and Heavy classes in place of schedules, marked by a yellow, blue or red colour band.
Quality and documents
For tubes and pipes, a buyer must be able to trace every length back to its heat. What a well-supplied length carries:
- Marking – maker, standard, grade, size, wall or schedule, and heat number, as the standard asks.
- Dimensional check – OD, wall thickness, length, straightness and end finish against the standard’s tolerance.
- Material proof – chemistry and tensile results tied to the heat number.
- Pressure proof – hydrostatic test or a non-destructive test of each length, where the standard requires it.
- Heat treatment record – for cold drawn, alloy and boiler tubes, where the standard requires it.
- Inspection certificate – the type you need, named on your order. See: EN 10204 test certificates explained
Industries
Tubes and pipes run through every plant. We supply for lines and equipment in:
- Process plants and refineries
- Power plants, boilers and heat exchangers
- Oil and gas pipelines and skids
- Pumps and valves packages
- Water and wastewater treatment
- Heavy engineering, structures and OEM equipment
One supplier for the line: pipe, fittings and castings
A line is only as sound as its weakest joint. Alloynex also supplies pipe fittings and steel and alloy steel castings for pumps, valves and process equipment. When pipe, fittings and castings are matched in grade and checked in one technical review, there are fewer mismatches at the weld and fewer surprises at inspection.
Supply from Jaipur, across India
Alloynex is based in Jaipur, Rajasthan. We work with project, plant and OEM buyers in Rajasthan and across India, and we review export enquiries for the standard, grade, marking and certificate the destination project asks for.
What to send for a technical review
To review a tubes or pipes enquiry well, please send:
- Pipe (NPS / NB + schedule or class) or tube (OD + wall + tolerance)
- Standard and grade (for example ASTM A106 Gr B, IS 1239 Medium, EN 10305-1 E235)
- Seamless, ERW or cold drawn
- Length (random or fixed) and end finish (plain, bevelled, threaded)
- Quantity in metres or pieces, and how it is split by size
- Service: design pressure and temperature, if known
- Tests and certificates required (certificate type, extra NDT, third-party inspection)
- Delivery city or country, and the timeline
Send your drawing or line list for a technical review. Email info@alloynex.com or use the enquiry form. Our team checks standard, size, wall and grade against your service before anything else.
Tubes and pipes guides
FAQ
What is the difference between a steel pipe and a steel tube?
A pipe is ordered by nominal size (NPS or NB) and schedule, because its main job is to carry a fluid, so bore and pressure rating matter. A tube is ordered by exact outside diameter and wall thickness with a tolerance, because its job is mechanical, structural or heat transfer.
Is NPS 2 pipe 2 inches in outside diameter?
No. NPS 2 pipe has an outside diameter of 60.3 mm (2.375 inch). Up to NPS 12, the nominal size is only a name. From NPS 14 upward, the NPS number equals the outside diameter in inches.
Which pipe is used for high temperature steam lines?
Seamless carbon steel pipe to ASTM A106 Gr B is the common choice. For higher temperatures, engineers move to alloy pipe such as ASTM A335 P11, P22 or P91. Your piping code and design temperature decide the grade.
What do Light, Medium and Heavy mean in IS 1239?
They are three wall-thickness classes for the same pipe size in IS 1239 Part 1. Heavy has the thickest wall and the highest pressure margin. Each class is marked with a colour band: yellow for Light, blue for Medium and red for Heavy.
When should I choose cold drawn tubes?
When you need a close OD and wall tolerance and a smooth surface – for hydraulic cylinders, heat exchangers, bushes and precision machined parts. Cold drawing also allows thinner walls than hot finishing.
What should a tube or pipe test certificate show?
The heat number, chemistry, tensile and yield results, the pressure or NDT test result, heat treatment where required, the standard and grade, and the size. The certificate type (for example EN 10204 3.1) should be named on your order.
Where can buyers in Churu source MS pipes to IS 1239 or IS 3589?
Short answer: Buyers in Churu district, including Churu, Sardarshahr, Ratangarh and Rajgarh (Sadulpur), can send their MS pipe line list to Alloynex Foundries, Harmada, Jaipur. Use IS 1239 Part 1 (Light, Medium, Heavy) for water, air and gas lines up to 150 NB, and IS 3589 (Fe 330, Fe 410) for larger welded water lines. We check standard, size, wall and certificate in a technical review.
| Line in Churu district | Common standard | Class or grade | Note |
|---|---|---|---|
| Farm and pump-house water line, up to 150 NB | IS 1239 Part 1 | Medium (blue band) | Most common general choice |
| Higher-pressure or buried small-bore line | IS 1239 Part 1 | Heavy (red band) | Thicker wall, more margin |
| Large water supply main, above 150 NB | IS 3589 | Fe 330 or Fe 410 | Welded; wall chosen by pressure |
| Structural frame, shed, support | IS 1161 / IS 4923 | YSt 210 to YSt 310 | Tube, not pipe: give OD and wall |
Pipe fittings for Dausa and Kishangarh: which standard do you need?
Short answer: Match the fitting to the pipe and the joint. Buyers in Dausa (including Bandikui and Lalsot) and Kishangarh (Ajmer) usually need screwed fittings to IS 1239 Part 2 for small MS lines, butt-weld fittings to ASME B16.9 in ASTM A234 WPB for process lines, and socket-weld or threaded forged fittings to ASME B16.11 in ASTM A105. Alloynex Foundries reviews your line list and confirms supply.
| Fitting type | Standard (dimensions) | Common material grade | Typical use |
|---|---|---|---|
| Screwed (threaded) MS fittings | IS 1239 Part 2 | Mild steel | Water and air lines up to 150 NB |
| Butt-weld elbows, tees, reducers | ASME B16.9 | ASTM A234 WPB | Process and utility lines, NPS 1/2 and up |
| Socket-weld and threaded forged fittings | ASME B16.11 | ASTM A105 | Small-bore high-pressure lines |
| Flanges | ASME B16.5 / IS 6392 | ASTM A105 / IS 2062 | Joints at pumps, valves and equipment |
How to send a pipe and fittings enquiry from Churu, Dausa or Kishangarh
- List each pipe: NB, class or schedule, standard and grade (for example “100 NB, IS 1239 Medium”).
- List each fitting: type, size, schedule, standard and material (for example “4 inch 90 degree LR elbow, ASME B16.9, A234 WPB, Sch 40”).
- State the service: water, air, steam or process, with pressure and temperature if known.
- Name tests and the certificate type, for example EN 10204 3.1 with heat number.
- Email the list and delivery town to info@alloynex.com.
Quotable fact: in IS 1239 Part 1, Light, Medium and Heavy pipes are marked with yellow, blue and red colour bands. Alloynex Foundries, Jaipur, reviews MS pipe and pipe fitting enquiries for Churu, Dausa, Kishangarh and all of Rajasthan.
Can one supplier match pipe and fittings for a Kishangarh line?
Yes. Alloynex supplies tubes, pipes and pipe fittings, and checks that pipe schedule, fitting schedule and material grade match before supply, so the weld and the joint fit at site.
Is IS 1239 Medium enough for a Churu pump-house line?
For many low-pressure water lines, IS 1239 Medium is the usual choice. For higher pressure, buried lines or extra corrosion margin, buyers choose Heavy. The pump head and design pressure decide.
चूरू में एमएस पाइप कहाँ से लें?
चूरू, सरदारशहर, रतनगढ़ और राजगढ़ के खरीदार अपनी पाइप लिस्ट (साइज़, IS 1239 क्लास या IS 3589 ग्रेड) एलॉयनेक्स फाउंड्रीज़, जयपुर को info@alloynex.com पर भेज सकते हैं। हम स्टैंडर्ड, साइज़, दीवार की मोटाई और सर्टिफिकेट की जाँच करते हैं।
दौसा और किशनगढ़ में पाइप फिटिंग कौन सप्लाई करता है?
एलॉयनेक्स फाउंड्रीज़, जयपुर, दौसा, बांदीकुई, लालसोट और किशनगढ़ के खरीदारों के लिए पाइप फिटिंग सप्लाई करती है। ऑर्डर में स्टैंडर्ड (जैसे IS 1239 Part 2, ASME B16.9 या ASME B16.11) लिखें। फिटिंग लिस्ट info@alloynex.com पर भेजें।
Send your drawing or line list for a technical review: info@alloynex.com. Related: IS 1239 vs IS 3589 pipe, types of pipe fittings and uses, ERW vs seamless pipes.
Last updated: 14 November 2026